Get a QuoteUpload your drawing

Sealing

IP68 Waterproof Aluminium Enclosures

IP68 quoted against the depth and duration on your drawing, and verified by hydrostatic immersion of the finished unit in still water.

IP68 is not a product that can be bought off a shelf. It is an agreement between buyer and supplier about two numbers — depth and duration — tested on the finished unit rather than on a bare box. Our standard range is IP65 to IP67. IP68 is quoted against the two numbers written on your drawing, because the same housing is not automatically good for a deeper or longer condition than the one it was tested to.

What has to be on the drawing

Ingress protection is defined by GB/T 4208, technically equivalent to IEC 60529. The first digit covers solids and the second covers water; the 8 in IP68 means immersion deeper than 1 m, with depth and duration agreed between buyer and supplier. A drawing that says only “IP68” leaves the two variables that decide the seal undefined, so we ask for them at enquiry stage and put them in the quotation.

The specification we work to

ItemValue
Rating quotedIP68 against an agreed depth and duration
Depth and durationAs written on your drawing, per GB/T 4208
Test methodHydrostatic immersion, still water, no pressure applied
Unit testedProduction configuration: gasket, fasteners and cable set installed
InspectionUnit opened after the hold and inspected for ingress
RecordsInspection records ship with the batch; the test repeats on production samples

The protocol is agreed before tooling, and the numbers we test to are normally deeper and longer than the service condition. A test at the service numbers proves the design works on the day of the test; testing with reserve proves the seal survives a few hundred thermal cycles and a lid that has been opened for service.

We do not substitute an air-pressure decay or leak-down check for immersion. A pressure test tells you a housing is airtight; it does not tell you a sealed enclosure survives being under water, and the two failures are not the same failure.

IP67 and IP68 are not the same housing

IP67IP68
Water conditionTemporary immersion, 1 m for 30 minImmersion beyond 1 m, depth and time agreed
Typical useShort flooding, a dropped unit in a sumpContinuous or repeated immersion
Groove and gasketStandard section for the enclosure sizeDeeper groove, larger gasket section, verified fill ratio
Lid stiffnessAdequate for occasional immersionChecked against the clamp load the gasket needs
Cable entryGland rated for splashGland or connector rated for the same depth

Moving from IP67 to IP68 usually changes four things at once: groove depth, gasket section, fastener pitch and the cable entry. Changing only the gasket is the most common reason a unit passes IP67 and fails IP68.

Where this housing is used

  • Outdoor machine-vision and inspection units that are washed down or stand in standing water
  • Roadside charging and power cabinets exposed to rain and pooling
  • Outdoor sensor and gateway housings on masts, roofs and poles
  • Energy-storage junction and control boxes in unheated outdoor installations
  • Dockside, marine and food-processing equipment where hosing is routine

How the seal is made repeatable

A single sealed sample proves the design; production needs the seal to be repeatable without a skilled fitter. Four things are fixed on the drawing rather than left to assembly:

  • Groove machined, not formed. Depth at 70–80% of gasket thickness, width 0.1–0.2 mm over the gasket, fill ratio not above 85%.
  • Gasket specified by number. Hardness in Shore A to GB/T 531.1 — EPDM 60±5, silicone VMQ 60±5, FKM 70±5 — and compression set to GB/T 7759.1 at 70 °C for 24 h, not above 25% for EPDM and VMQ.
  • Groove masked through finishing. Powder or anodising inside the groove changes the compression by more than the tolerance, so the seal area is machined before finishing and masked during it.
  • Continuous loop, no glued corner. Moulded corners or a die-cut continuous loop; a cut-and-glued joint is the first leak path on a rectangular lid.

What we need from you

Send the enclosure drawing with the IP target, the depth and duration, where the cables enter and with which gland, the gasket material you have approved (if any), the temperature cycle the unit sees, and any cleaning chemical it is exposed to. With those, the groove and gasket specification comes back with the quotation rather than after a failed tank test.

Questions buyers ask

Can you guarantee IP68 on a standard enclosure?

No, and a supplier who says yes without asking for a depth and a duration is guessing. IP68 is defined by those two numbers, so we quote against them and test the finished unit to them.

Do you use air-pressure testing instead of immersion?

No. The acceptance test is hydrostatic immersion of the finished unit. A pressure-decay check is a production convenience on some products, but it is not evidence that a sealed enclosure survives immersion.

Which gasket material should I specify?

EPDM 60 Shore A covers most outdoor and general electronics enclosures. Silicone for a wide temperature range, FKM where oil or fuel is present. Hardness to GB/T 531.1 and compression set to GB/T 7759.1 so the part can be inspected against a number.

Send the drawing with the depth and duration you need — we will return a groove and gasket specification with the quote.