An IP rating is a promise about the joint, not the metal. Aluminium is already waterproof — what leaks is the seam between lid and body, the cable entry, and the fastener holes. When a design that passed on the bench comes back from the field, the cause is almost always one of four things, and none of them is the gasket material.

These are the failures we look for at DFM stage, in the order they actually occur.

1. The sealing land was anodised

Anodic film grows at a rate that varies across a surface, and the gasket then seats on a plane that is no longer flat. Compression varies around the perimeter, so one section seals and another does not. The symptom is a unit that passes a jet test on the bench and weeps after a few months outdoors.

Fix: mask the land before anodising, or machine it after finishing. Either way the note belongs on the drawing, because the finishing shop cannot infer it.

2. Fastener pitch is wider than the lid can carry

The lid bows between screws. At the midpoint of each span the gasket decompresses below its sealing stress, and that midpoint is where the water arrives. It gets worse with thin lids, wide flanges, and any gasket that has taken a set.

Fix: space fasteners every 50–100 mm on a machined aluminium flange, closer as the lid gets thinner, and add compression stops so the joint bottoms out at the correct deflection rather than depending on torque.

3. Sharp internal corners stop the gasket filling the groove

A square internal corner is where a moulded or cut gasket bridges instead of sitting down, leaving a void exactly where two sealing runs meet. The same applies to a groove that is over-filled: if the gasket has nowhere to deform, it bulges out of the groove rather than pressing against the land.

Fix: radius internal corners, keep groove fill at 70–90%, and use a continuous moulded gasket rather than four cut strips mitred at the corners.

4. Mixed metals at the fastener

A stainless screw in an aluminium housing is a galvanic couple, and water is the electrolyte. The aluminium around the screw corrodes, the clamping force drops, and the seal opens — slowly, which is why it is missed.

Fix: stainless fasteners with isolating washers, a sealed thread insert, and a finish that covers the cut edge of every hole.

The four, side by side

FailureWhat you seeFix
Anodised landBench test passes, field unit weepsMask the land, or machine after finishing
Wide fastener pitchWater at the midpoint between screws50–100 mm pitch plus compression stops
Sharp internal cornersLeak at a corner, gasket visibly bridgedRadius corners, 70–90% groove fill, moulded gasket
Mixed metalsWhite corrosion around screws, loose clampIsolating washers, sealed inserts, finished hole edges

Two more that are not the joint at all

  • Cable entries. In returns this outranks the lid gasket. A gland has to match the cable's measured diameter, and every unused entry needs a rated blind plug.
  • Condensation. No IP test catches it. A sealed box breathes humid air in, the temperature drops, and water forms on the inside of the lid. A rated ePTFE vent or a correctly sized desiccant deals with it; the gasket never will.

Validate on the real assembly

Test with the production gasket, the production fasteners and the real cable set installed. A bare box that passes immersion tells you the groove geometry is right and nothing about the system.

If you need a specific rating, tell us the level and the environment and we will design the joint and, where required, run a sample through water-jet and immersion tests. Our surface treatment FAQ covers which finishes are compatible with a sealing land. Ready to seal a design? Send the drawing for a free DFM review.

Have a project in mind? Send your drawing and get a DFM review plus tooling quote within one working day.