A heat sink enclosure does two jobs with the same piece of metal: it holds the electronics and it carries heat out of them. In an extruded profile the fin geometry is created by the die, so once the tool exists another fin costs almost nothing — which is why extrusion still beats a machined fin array for anything past prototype volume. What the die cannot do is fix a thermal design that was decided after the section was drawn.
What the die can and cannot hold
These are production numbers from our own presses, not a catalogue maximum:
| Parameter | Typical capability | Why it matters |
|---|---|---|
| Fin thickness | 0.3–1.2 mm | Thinner fins raise density inside the same envelope |
| Fin height | Up to about 60 mm | Sets the convection area available |
| Aspect ratio | Up to about 15:1 | Beyond this the die lips deflect and fins wave in volume |
| Base alloy | 6063-T5, about 209 W/m·K | 6061-T6 where the housing also carries structural load |
| Mounting face flatness | About 0.05 mm after machining | Keeps the thermal interface layer thin |
| Cut-to-length | ±0.02 mm on CNC-faced ends | Repeatable stack-up in automated assembly |
| Maximum section | 220 mm circumscribing circle, 6 m length | Sets the largest single-piece housing |
Natural convection or forced air — decide before the section
The same fin pitch is right for one and wrong for the other, and the drawing cannot be changed cheaply once the die is cut. Tell us which regime applies at enquiry stage:
- Natural convection. Air has to be able to enter and leave the channel, so fin spacing is set by the boundary layer rather than by how many fins will fit. Orientation matters: a vertically finned housing draws air through the channels, the same housing laid flat stalls. Aesthetically tight fin arrays often fail here.
- Forced air. Tighter pitch and taller fins pay off because the airflow thins the boundary layer, but pressure drop rises with fin density — a fan chosen for a bare housing may not move the same air through a dense array. Ducting the flow over the fins is usually worth more than another two fins.
- Sealed or potted units. If the electronics cavity is sealed to IP65 or better, heat reaches the fins only through the base. Fin geometry still matters, but base thickness and the mounting interface dominate, and the housing becomes a heat spreader before it becomes a heat sink.
What we need to propose a section: dissipated power, allowable case temperature, ambient temperature, airflow (free or forced, and roughly how much), mounting orientation, and the envelope you can give away.
Fin pitch, fin height and the point of diminishing returns
Adding fins adds surface area, but not in a straight line. Each extra fin sits in the thermal boundary layer of its neighbour, and each taller fin runs at lower efficiency because heat has to travel further along the fin before it reaches the air. Past the aspect ratio the die itself becomes the limit: the lips deflect under pressure and the fin waves along the length, which is a scrap problem rather than a tolerance conversation.
In practice this means a redesign usually beats a bigger housing. The case below cut operating temperature by 8 °C inside an unchanged envelope by reworking pitch and height and using 0.3 mm fins to raise density — no new form factor, no change to the industrial design.
Finish is part of the thermal design
- Black anodising raises emissivity, which matters on a passively cooled housing radiating to a cooler surrounding surface.
- Natural anodising is the default where convection dominates and the finish is specified for corrosion resistance.
- Powder coating is a thicker, more insulating layer. It is the right choice when the housing is also a visible exterior part, but it should be declared before the thermal budget is signed off, not after.
- Masking keeps coating and anodising out of the mounting face and out of threads; a coated pad adds a layer between the device and the metal.
The mounting interface decides more than the fins
A flat, clean mounting pad lets the thermal interface material stay thin and uniform. A pad that is flat to about 0.05 mm and free of machining burrs is worth more than an extra fin row, because the interface resistance sits in series with everything the fins can do. Where the device needs electrical isolation from the housing, an anodised layer can provide it — but then the anodising is part of the thermal stack and has to be specified as such, at a controlled thickness, rather than left to the finishing line.
Case: 8 °C lower inside an unchanged envelope
A Japanese lighting OEM had a luminaire running hotter than its service-life claim could support, with the industrial design frozen and no budget for a new form factor. We re-optimised fin pitch and height inside the existing section, used 0.3 mm fins to raise density without growing the housing, machined the LED board mounting face for flatness, and confirmed the result on physical samples before volume. Operating temperature fell by 8 °C. Read the case study.
Questions buyers ask
Can you hit a target thermal resistance rather than just a drawing?
Yes, and it is usually the better place to start. Give us the dissipated power, allowable case temperature, airflow condition and envelope, and we will propose a fin section and tell you the predicted performance. If the target cannot be met by extrusion alone we say so at that stage instead of shipping parts that miss the specification.
Is an extruded heat sink cheaper than a machined one?
Past prototype volume, almost always. The fin geometry is formed by the die rather than by cutting time, so the per-piece cost falls sharply once the tooling is amortised. Below that, machining from solid bar avoids tooling spend — see low-volume production.
How do you keep fin geometry consistent batch to batch?
The die defines the section, so the variables are press stability and post-extrusion handling. Wall thickness is held to ±0.02 mm against a GB standard of ±0.05 mm, and dimensional reports can ship with each batch.
Send the dissipated power, the allowable case temperature and the envelope — we will come back with a fin section proposal and a tooling quote within one working day.