Short answer: an IP rating answers two questions — dust and water — and nothing else. An outdoor enclosure also has to survive UV, salt fog, thermal cycling and condensation, and those four are decided by alloy, surface treatment, thermal design and venting rather than by the gasket.

Choosing the rating from the exposure

InstallationRating to specify
Sheltered, indoor, occasional splashIP54
Open air, rain and hose wash-downIP65
Driving rain, pressure wash, vehicle-mountedIP66
Occasional flooding, snow pack, low-level submersionIP67 — 1 m for 30 min
Permanent submersionIP68 at an agreed depth, with a pressure test

Specifying one grade above the exposure is normal engineering margin. Specifying IP68 "to be safe" is not: it forces a different sealing architecture and a test regime that has to be repeated on every design change.

The four things IP does not cover

1. UV

Aluminium does not degrade in sunlight, but the finish can. Anodising is inherently UV-stable; powder coatings need a polyester or PVDF chemistry rather than a generic epoxy, which chalks and fades outdoors. Gaskets matter too — EPDM and silicone both resist UV and ozone, while cheap nitrile does not.

2. Salt fog

Coastal and marine sites attack the enclosure at three points: the coating itself, every fastener, and every cut edge where bare metal is exposed. The workable combination is a sealed anodic or thick powder finish, stainless fasteners, and isolating washers wherever stainless meets aluminium to break the galvanic couple. A salt-spray test on the finished assembly is the only credible evidence.

3. Thermal cycling

A sealed housing in direct sun can run far above ambient, then drop at night. That cycle works on the gasket, the sealant and any bonded window. Two consequences: pick a gasket with low compression set (silicone rather than a cheap blend), and check that the lid and body expand at similar rates — mixed materials move differently and open a gap at the extremes.

4. Condensation

This is the failure that IP ratings never catch. A sealed box breathes in humid air on a warm day, then the temperature drops, and water condenses on the inside of the lid — directly above the electronics. The fixes are a pressure-equalisation vent with an ePTFE membrane so vapour can escape without liquid entering, a desiccant pack sized to the internal volume, or conformal coating on the board itself.

Alloy and finish for outdoor service

Thermal management in a closed box

Sealing removes convection. An outdoor housing that was fine with vents will run hotter once it is IP67, and the derating shows up as random resets rather than an obvious failure. Three levers: use the aluminium body as the heat sink (fins outside, flat machined pads inside), couple the hottest component to the wall with a gap pad rather than air, and lower the internal heat load before adding surface area — a 10 °C reduction in load is often cheaper than 20% more fin.

Installation details that decide field life

FAQ

Is IP67 enough for coastal installation?

It handles the water, not the salt. Add a finish validated by salt-spray testing, stainless fasteners with isolation, and a vent to control condensation.

Can a sealed enclosure have a breather?

Yes — a rated ePTFE vent equalises pressure while blocking liquid water, and it usually improves long-term sealing performance rather than compromising it.

Does anodising survive UV?

The anodic film itself is stable. What fades is the dye, so specify a colour-fast dye and a sealed film if appearance matters over a decade outdoors.

Send the exposure, not just the rating

Tell us where the enclosure is installed — coastal, inland, vehicle-mounted, submerged — and we will propose the rating, alloy, finish and venting that fit it, with a sample for testing before tooling.