±0.04 mm on inner/outer diameter and ±0.02 mm on wall thickness is our production standard for aluminium enclosures — about 2.5× tighter than the GB national standard. What it covers, what tighter costs, and how to specify it.
What the numbers actually cover
| Dimension | Our production standard | GB national standard |
|---|---|---|
| Inner / outer diameter | ±0.04 mm | ±0.10 mm |
| Wall thickness | ±0.02 mm | ±0.05 mm |
| Cut-to-length (CNC-faced ends) | ±0.02 mm | — |
| Minimum stable wall | 0.3 mm | — |
Why the national standard is not a capability
GB tolerance is the floor a supplier must clear, not the best they can do. A factory quoting ±0.10 mm is telling you what it will guarantee, not what its machines can hold. Holding ±0.04 mm in volume depends on two things upstream of the spindle: consistent billet (primary 6063, ceramic-filtered, degassed and homogenised, so there are no sand holes or weld lines) and stock that is straightened before it is machined.
What going tighter actually costs
Tolerance is free only until it forces a second setup. Below about ±0.02 mm you are paying for a dedicated fixture, a lighter finishing pass, in-process gauging and full inspection — not for a better part. The most common waste we see is a drawing that calls ±0.02 mm on all dimensions; mark the two or three features that control fit and let the rest run at general tolerance.
How to specify tolerance on your drawing
State a general tolerance note for the whole part, then call out only the critical features. Define a clear datum scheme — bore spacing, sealing face and mounting datum are the usual candidates. Say whether dimensions are measured before or after anodising, because the anodic layer adds thickness. And ask for the inspection report up front rather than after the first shipment.
Verification
Every batch can ship with a dimensional report of measured values, at no extra charge. That report is also the fastest way to settle a fit dispute with your assembly line.
Quick answers
- Standard tolerance: ±0.04 mm ID/OD, ±0.02 mm wall, ±0.02 mm cut-to-length on CNC-faced ends.
- Can you hold ±0.01 mm? On specific features, yes — with a dedicated fixture and full inspection; quoted per feature.
- Does anodising change dimensions? Yes, the oxide layer adds thickness; tell us which dimensions are pre- or post-finish.
- Extruded vs machined surfaces: profile surfaces follow extrusion tolerance; machined bores, faces and grooves are held to ±0.04 mm or tighter.
- Inspection report: dimensional report per batch, free of charge.
Have a project in mind? Send your drawing and get a DFM review plus tooling quote within one working day.